IIS 7.0-hosted Web site error message: "HTTP Error 500.19 - Internal Server Error"

You have the Internet Information Services (IIS) 7.0 to host the site. When you visit Web browser, a Web site, you may receive one similar to the following error message:
Error message 1

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x8007000d
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Error message 2

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x80070005
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Error message 3

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x800700b7
HResult description of the configuration data related to this page is not valid, you can not access the requested page.

Error message 4

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x8007007e
HResult description of the configuration data related to this page is not valid, you can not access the requested page.

Error message 5

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x800700c1
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Error message 6

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x800700b7
HRESULT description of the configuration data related to this page is not valid, you can not access the requested page.

Error message 7

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x8007010b
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Error message 8

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x8007052e
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Error Message 9

Application "application name" in the server error
HTTP Error 500.19 - Internal Server Error
HRESULT: 0x80070021
A description of the HRESULT relevant to this page because the configuration data is invalid, you can not access the requested page.

Back to the top

Reason

The reasons for the error message 1

Because the file or Web.config file contains ApplicationHost.config malformed XML element, so this problem occurs. To resolve this problem, see solution 1.
Back to the top

The reasons for the error message 2

This problem occurs because one of the following reasons:

  • You are using a computer running Windows Vista on IIS 7.0. In addition, you configure to use UNC Passthrough authentication to access the remote site Universal Naming Convention (UNC) share.
  • IIS_IUSRS group ApplicationHost.config file or Web.config file does not have the appropriate permissions.

To resolve this problem, see Resolution 2.
Back to the top

The reasons for the error message 3

Because the file has the following code ApplicationHost.config duplicate entries, so this problem occurs.

< Add  accessType="Allow" users="*" />

To resolve this problem, see solution 3.
Back to the top

The reasons for the error message 4

As ApplicationHost.config file or Web.config file references invalid or non-existent module or DLL, so this problem occurs. To resolve this problem, see solution 4.
Back to the top

5 reasons for the error message

If the specified number of bits in the module with the host application's application pool of bits is different, this problem may occur. For example, the component tries to load 32-bit to 64-bit applications. If the specified module is damaged, this problem may also occur.
Back to the top

The reasons for the error message 6

This problem may occur if the configuration hierarchy (for example, the parent site / folder or applicationHost.config web.config file), for the higher level specified in the configuration part of the set there are duplicate tiaomu, this problem may occur . The error message itself pointed out that the location of duplicate entries or entries.
Back to the top

7 reasons for the error message

If you can not access the specified contents of the directory, this problem occurs.
Back to the top

8 reasons for the error message

IIS 7.0 in the default process identity does not have enough permissions to open the Web.config file on the remote share.
Back to the top

9 reasons for the error message

When the designated part of the IIS configuration files configuration at a higher level is locked, this problem may occur.
Back to the top

Solutions

Solution 1

File or the Web.config file from ApplicationHost.config remove malformed XML element.
Back to the top

Solution 2

To resolve this problem, use the following methods.

Method 1

Do not configured to use UNC Passthrough site authentication to access the remote UNC share. Instead, specify the user account has the appropriate permissions to access the remote UNC share.

Method 2

File or the Web.config file for ApplicationHost.config, grant read access to the IIS_IUSRS group. To do this, follow these steps:

  1. In Windows Explorer, locate the site associated with ApplicationHost.config files, or find the site associated with the Web.config file.
  2. Right-click ApplicationHost.config file, or right-click the Web.config file.
  3. Click "Properties."
  4. Click the "Security" tab, then click "Edit."
  5. Click "Add."
  6. In the "Enter the object names to select" box, type computername \ IIS_IUSRS, click the "Check Name", then click "OK."

    Note Computername is a placeholder for the computer name.

  7. Click to select the "Read" check box, then click "OK."
  8. In the "ApplicationHost.config Properties" dialog box or "Web.config Properties" dialog box, click "OK."

Back to the top

Solution 3

In ApplicationHost.config file, delete the authorization rules of the duplicate entries. To do this, follow these steps:

  1. Click the "Start" in the "Start Search" box, type Notepad, right-click "Notepad", then click "Run as administrator."

    Note If you are prompted for an administrator password or confirmation, type the password, or click "Continue."

  2. In the "File" menu, click "Open" in the "File Name" box, type% windir% \ System32 \ inetsrv \ config \ applicationHost.config, and then click "Open."
  3. In ApplicationHost.config file, similar to the following code to delete duplicate entries.
    < Add  accessType="Allow" users="*" />
    

Back to the top

Solution 4

File or the Web.config file in the ApplicationHost.config, find or DLL module reference invalid references, and fix this reference. To determine which module reference is not correct, enable failed request tracing, and then reproduce the problem.
Back to the top

Solution 5

To ensure that the number of bits specified module with the host the same application pool, and to ensure that the module is not damaged.
Back to the top

Solution 6

Check the specified configuration file and its parent applicationHost.config and / or compare the web.config file to check the error message that duplicate entries. Remove duplicate entries, or make entries only.
Back to the top

Solution 7

Verify that the file path exists and whether the correct name, is set the correct file level permissions, and points to a valid file system type. If you are unsure what is the file path, use the process monitoring tools or Failed Request Tracing its identity.
Back to the top

Solution 8

To resolve this problem, please see the following article:
934515 When you try to Internet Information Services 7.0 pass-through authentication from the use of the site view web pages, you receive an error message

Back to the top

9 Solutions

To resolve this problem, unlock the specified part, or not that level to use it. For more information on configuring the lock, see the following article:
http://learn.iis.net/page.aspx/145/how-to-use-locking-in-iis-70-configuration

分类:DotNet 时间:2011-05-30 人气:291
分享到:
blog comments powered by Disqus

相关文章

  • HTTP/1.1 500 Internal Server Error 2010-11-15

    HTTP/1.1 500 Internal Server Error collection I found a more effective solution, because it is to get rid of my problem, so I think it is very effective, probably will vary it, do not say nonsense, and have a look it: First of all ie - tools-internet

  • IIS server to resolve "HTTP 500 internal server error" 2010-07-29

    Today, the IIS server computer students suddenly go wrong, let me help myself, I looked at his system is Windows XP SP2, IIS version 5.1, fault phenomenon is in the browser address bar enter http://127.0 .0.1 / , there are new "HTTP 500 Internal Serv

  • Windows XP SP3 IIS HTTP 500 - Internal Server Error solution 2010-12-15

    Windows XP SP3 IIS installation package to download http://222.76.208.4/upload/IIS_XPSP3.rar When the system update sp3 after installation of iis, you will be prompted to insert the sp3 CD, because now Microsoft has not launched a mirror version of s

  • IIS HTTP 500 internal server error occurred solutions 2010-08-24

    Original Address: http://www.lizhongda.net/info/news_detail.asp?newsid=528 The first solution: 1. Run: regsvr32% windir% / system32/vbscript.dll 2. Run: msdtc-resetlog 3. Re-install IIS Notes: 1. Microsoft only provides a management with IIS5 script

  • DotNet storage space on the Godaddy site appears 500 - Internal server error Error Summary 2010-11-18

    Recently with DotNet2.0 + sql server 2005 made a website in the server machine and runs well on its own, but has been put on Godaddy space the following error: 500 - Internal server error. There is a problem with the resource you are looking for, and

  • Fckeditor XML Request error:internal server error (500) 解决方法小结 2015-03-09

    本文章收藏了关于FCKEditor XML Request Error:Internal Server Error(500)各种问题的解决办法 原来一直能用的ecshop后台信息发布里面的fckeditor上传功能,换了个机器后不能用了.以为是文件损坏,上传一边不行. 什么xml错误,还弹出一个大的JavaScript alert警告框,内容就是服务器端错误的500内容 网上搜,又说是配置问题,主题问题,想想都不应该,直接请求 filemanager/connectors/php/connect

  • HTTP 错误 500.19 - Internal Server Error 无法访问请求的页面,因为该页的相关配置数据无效. 2014-05-07

    HTTP 错误 500.19 - Internal Server Error 无法访问请求的页面,因为该页的相关配置数据无效. 详细错误信息模块 IIS Web Core 通知 BeginRequest 处理程序 尚未确定 错误代码 0x80070005 配置错误 由于权限不足而无法读取配置文件 配置文件 \\?\C:\Users\Administrator\Desktop\Z-Blog18\web.config 请求的 URL http://127.0.0.1:80/default.asp 物

  • HTTP 错误 500.19 - Internal Server Error 2015-02-05

    往常习惯在web.config文件里添加 配置节点 默认文档 内容如下: --web.config(你懂得!) <configuration> <system.webServer> <defaultDocument> <files> <add value="Default.aspx"/> </files> </defaultDocument> </system.webServer> <

  • Internal Server Error PHP 2011-04-08

    [Error]: Internal Server Error The server encountered an internal error or misconfiguration and was unable to complete your request. Please contact the server administrator, admin @ localhost and inform them of the time the error occurred, and anythi

iOS 开发

Android 开发

Python 开发

JAVA 开发

开发语言

PHP 开发

Ruby 开发

搜索

前端开发

数据库

开发工具

开放平台

Javascript 开发

.NET 开发

云计算

服务器

Copyright (C) codeweblog.com, All Rights Reserved.

CodeWeblog.com 版权所有 黔ICP备15002463号-1

processed in 0.491 (s). 12 q(s)